Materiale diviso per argomento di Life Support Systems per il corso di Biomedical Engineering presso Politecnico di Milano. Il documento tratta: ECMO AND MECHANICAL VENTILATION We were about ending in terms of respiratory blood. You should have understood that respiratory assistance can be performed on the blood side by connecting the patient to extracorporeal circulation, but just partially, that is 80% of the overall…
Materiale diviso per argomento di Life Support Systems per il corso di Biomedical Engineering presso Politecnico di Milano. Il documento tratta: ECMO AND MECHANICAL VENTILATION We were about ending in terms of respiratory blood. You should have understood that respiratory assistance can be performed on the blood side by connecting the patient to extracorporeal circulation, but just partially, that is 80% of the overall…
Qualità dell’importazione: il testo è stato estratto direttamente dal documento originale.
Passaggi rappresentativi riconosciuti nelle diverse parti del materiale. Il testo completo resta presente nella pagina per la ricerca, mentre l’anteprima compatta rende più semplice la lettura.
ECMO AND MECHANICAL VENTILATION We were about ending in terms of respiratory blood. You should have understood that respiratory assistance can be performed on the blood side by connecting the patient to extracorporeal circulation, but just partially, that is 80% of the overall flow rate, and the circuit is much shorter than the one that is used for extracorporeal circulation. There are still two elements to be analysed: one is the fact, that we already went through this, that the patients after some days need to be assisted with a new oxygenator. I said this many times because of the adhesion of biological components to the membrane that reduces the capacity of transferring gas. Gas transfer is impaired after some days of assistance. The oxygenator must be changed. And as we already said, I'm just recalling the last element: membranes that are used are wonderful silicone membranes and nowadays polypropylene or polymates. In these systems, the membranes are normally produced in the form of fibers, similar to those used in a dialyzer: blood flows outside the fiber while gas flows inside. Although we have already briefly mentioned why this arrangement differs from dialysis, we did not explore the topic in depth. The circuit is set up as follows: the patient is connected directly to the circuit, with no reservoirs present. The circuit includes a pump and a membrane blood oxygenator, after which blood is returned to the patient. ECMO main technical advances are in 4 areas: 1. Switch from VA to VV ECMO: helped by the widespread use of a wide size range of double-lumen veno-venous cannulae. 2. Switch from roller to centrifugal pumps that do not damage the red blood cells (most of the main manufacturers provide these systems). 3. Switch from silicone membrane oxygenators to…
another, so there are no compressions and no direct mechanical relationship between pressurization and red blood cell damage. However, these pumps also have problems. Like all centrifugal pumps, due to their design, they work perfectly within a certain flow rate range but perform poorly, to be more clear, lower flow rates compared to the design specifications. This is because, depending on the shape of the conical channel, we need a correct transformation from velocity into pressure, which is the core of the energy conversion process. This behaviour is valid for a certain range of flow rates related to the specific dimensions of the pump. If the flow rates are too low or too high with respect to this range, the pump risks causing haemolysis due to the acceleration or deceleration that can occur through the channel. That said, centrifugal pumps are much safer overall. We are fortunate because during ECMO the flow rate is almost constant; in this application, the pumps do not experience significant variations in the flow rate passing through them. The machine is set to, say, 4 Liters per minute, and the pump will deliver exactly 4 Liters per minute of blood. Some stress can still occur, but much less than with roller pumps. Centrifugal pumps have another advantage: they are small, so their priming volume is low. However, the priming volume of a roller pump is also somewhat low. One might say, incorrectly, that a roller pump has no priming volume at all because it uses only the tubing segment of the circuit. Of course, that tubing must be added to the circuit because it is necessary. From the perspective of a centrifugal pumping system, such a system is acceptable, but all these pros and cons must be considered. Ultimately, it would be important to use different…
need this kind of support. A key difference with this type of ventilation is that patients can drink and eat because respiration is supported directly through the trachea, which is somewhat better for nutrition than relying solely on assisted feeding. Of course, it is important to humidify the air; otherwise, we return to the issue mentioned earlier, it would be identical to breathing air that is too cold due to incorrect humidification, since all cells need to be properly humidified. Therefore, this kind of system also requires a small humidification device. Therefore, with correct temperature and correct humidity of the air, the patient can be assisted. However, pay attention not to cause over-pressurization of certain sites. This is crucial: on the pathological side, there may be restrictions, requiring higher pressure to reach those areas. But if high pressure is applied, the system is not homogeneous. The system will follow the path of least resistance, it is easier to inflate regions that are already compliant, so some parts become over-pressurized and may undergo structural damage. For this reason, it is important to maintain an overview of the entire distribution of airflow and to ensure the correctness of distribution across the different lung areas. This is a brief scheme of respiratory failure. You will see all the elements connected to the system, including the relationship between therapy and pathology, the matching between the two. It is important to understand that this kind of ventilation can lead to very serious problems if the respiratory system (the tracheobronchial tree and its subdivisions) is not homogeneously affected by the pathology. This is something that needs to be carefully reviewed. Whether we use invasive or non-invasive ventilation,…
oedema, as it helps to reduce Patients who are very sensitive to preload (lung congestion) and change in preload conditions afterload. As a result, stroke (e.g., presence of hypovolemia, volume tends to increase. tamponade, PE, severe air trapping) are particularly prone to hypotension when PPV is initiated. Therefore, the machine must be set in a correct way. To determine whether the patient is developing acidosis or other issues, we can use blood samples. We take blood samples and analyse them in a blood gas analyser, measuring pO₂ and pCO₂ from both arterial and venous blood. This allows us to know with certainty whether the rate and settings of our machines are appropriate. The key elements to monitor are not only oxygen saturation but also pO₂ and pCO₂ from venous and arterial samples, these are three important parameters. In non-invasive ventilation, of course, the entire system is simpler, and the patient is easier to treat because the patient is not suffering from excessively severe pathologies. Advantages of NIPPV Disadvantages of NIPPV Allows the patients to maintain Less airway pressure is normal functions tolerated • Speech Does not protect against • Eating aspiration Helps avoid the risks and No access to airway for complications related to: suctioning • Intubation • Sedation→ Less ventilator- associated pneumonia This allows us to determine whether the respiratory support is succeeding or can be improved. The support is produced by the machine, and clinicians need to set the machine correctly to achieve proper oxygenation and harmonization of the blood, that is, to reach correct pO₂, pCO₂, and saturation levels during the respiratory phase, using both arterial and venous values. This gives us an idea of the advantages and the quality of support…
damaged or not by the procedure. The results we obtained were fantastic, and in fact we published several papers on this topic. So, in the dark, liquid ventilation is still used occasionally, but it has absolutely not been taken into consideration for premature newborn babies with respiratory distress. As a result, newborns today still must be treated either with ECMO (which requires central cannulation and open chest) or with mechanical ventilation, both of which damage them. For the little ones, good ventilation systems remain a problem. Histological examinations of the lungs from the treated animals looked perfect. The liquid did not impede any physiological growth, nor did it hinder any possibility of normal development. Yes, liquid ventilation can be used. It is used in some specific cases and particular situations, and it has even appeared in the news recently. However, it is not widespread. Its application requires clinicians who are truly expert. Beyond the well-known applications, processing a liquid is inherently different from processing a gas. Liquid ventilation is certainly healthier for the respiratory tree because it distributes more uniformly, whereas gas can be more uneven. Nevertheless, it is important to have specific know-how to control the correct distribution of the fluid, how to oxygenate it, how to ensure that oxygen has been transferred and carbon dioxide removed. So, it is somewhat complex in terms of overall evaluation of the therapy. It is interesting, and it has been done in adults. But adults are problematic whereas the much more problematic patients are newborns or preterm newborns. Preterm newborns are not so few. Depending on the month of gestational age, if they are delivered at the fifth month, many other problems are present.…
Prima pagina del documento.