DIPARTIMENTO DI SCIENZE E TECNOLOGIE AEROSPAZIALI IMPIANTI E SISTEMI AEROSPAZIALI Laboratorio n.9 – A.A. 2021/2022 IMPIANTO DI CONDIZIONAMENTO Dati : 2m = 250 kg/h p1 = 101325 Pa p2/p1 = 3.2 p3 = .95 p2 p4 = p5 = p6 = p1 p7 =.95 p1 T4 = 5 °C calcolare per i due casi di temperatura al punto 1 di 10°C e di 34°C: • la ripartizione di portata richiesta fra il ramo “caldo” ( 5m ) ed il ramo “freddo” ( 4m ) per avere nel punto 6 la temperatura di 2 2 °C quando quella esterna è di 3 4°C e di 2 4°C quando quella esterna è di 10°C. • la portata d’aria ( 7m ) necessaria nello scambiatore di calore per ottenere le temperature indicate e la temperatura T8. Coefficiente politropica valvola A: 05.1= Coefficiente politropica valvola B: 37.1= Efficacia dello scambiatore: 8.)( )( 727 323 =− −= TTm TTm Rendimento del compressore: 9.=c Rendimento della turbina: 9.=t B A 1 2 3 4 5 6 7 8