AY 2019 20 Test 5 Numerical part with solutions

Full exam for Electric Conversion From Green Sources of Energy in the Energy Engineering degree programme at Politecnico di Milano. The document covers: ELECTRIC CONVERSION FROM GREEN SOURCES OF ENERGY Prof. Alberto Dolara Numerical exercise 1 < 19 February 2021 > The numerical data of this problem depend on your ID number, as follows: Example: ID number = 10123456 → U = 1, V = 2; W = 3; X = 4; Y = 5; Z = 6. Numerical data that

Electric Conversion From Green Sources of EnergyFull exam

Document information

What's included in this study material

Full exam for Electric Conversion From Green Sources of Energy in the Energy Engineering degree programme at Politecnico di Milano. The document covers: ELECTRIC CONVERSION FROM GREEN SOURCES OF ENERGY Prof. Alberto Dolara Numerical exercise 1 < 19 February 2021 > The numerical data of this problem depend on your ID number, as follows: Example: ID number = 10123456 → U = 1, V = 2; W = 3; X = 4; Y = 5; Z = 6. Numerical data that

Import quality: text was extracted directly from the original document.

Extracted content from the document

Representative passages recognised in different parts of the material. The full extracted text remains available to search, while this compact preview makes the page easier to read.

Page 1

ELECTRIC CONVERSION FROM GREEN SOURCES OF ENERGY Prof. Alberto Dolara Numerical exercise 1 < 19 February 2021 > The numerical data of this problem depend on your ID number, as follows: Example: ID number = 10123456 → U = 1, V = 2; W = 3; X = 4; Y = 5; Z = 6. Numerical data that depend on your ID number are highlighted by the symbol “←” along the text. A power processor for photovoltaic (PV) generator is composed by the cascade connection of a DC/DC converter , a three-phase PWM inverter and a line -frequency step -up three -phase transformer. Power processor ratings and technical data are the following: ► PV generator voltage range, VPV from 300 V to 1000 V ► Rated power, Pn 250 kW ► Rated power factor, cosϕn 1 ► Rated frequency, fn 60 Hz ► Transformer rated voltage, high-voltage side, VHVn 15 kV (RMS, line to line) ► Transformer rated voltage, low-voltage side, VLVn 330 V (RMS, line to line) ► Transformer rated power, An 250 kVA ► Transformer short circuit voltage, vcc% 5 % ► Inverter LC output filter, inductance, L 125 μH ► Inverter LV output filter, capacitor, C 180 μF Calculations: 1. Calculate the DC bus voltage that allow the inverter to operate in the linear region when the grid voltage is (100 + X) % ← the rated grid voltage (that is VHVn), for any output power. Consider the following assumptions:  Transformer windings resistance negligible.  Transformer no-load current negligible.  Current in the capacitor of the LC filter negligible. 2. Choose the type of DC/DC converter suitable for interfacing the photovoltaic generator to the inverter, and calculate the duty cycle range ( minimum and maximum value ). Consider the DC bus voltage previously calculated. 3. Calculate the minimum frequency modul ation ratio m f that allows to attenuate the amplitude of the…

Preview

First page of the document.

First page: AY 2019 20 Test 5 Numerical part with solutions