ESERCITAZIONE CICLONI Impianti Chimici 2 Si alimenta il ciclone di figura con una portata di aria pari 0.25 m^3/s. La distribuzione dei diametri del particolato solido è la seguente: Si determini l’efficienza di separazione. A H B R D (micron) %numerica <3 2 3-5 8.5 5-10 10 10-15 17 15-25 25 25-30 18 30-35 12 >35 7.5 visc (Pa s) 1.00E-05 ro gas (kg/m^3) 1 ro part (kg/m^3) 2000 B (m) 0.45 H (m) 0.15 R (m) 0.8 A (m) 1.35 Q(m^3/s) 0.25 Risoluzione visc (Pa s) 1.00E-05 D (micron)%numerica ro gas (kg/m^3) 1 <3 2 ro part (kg/m^3) 2000 3-5 8.5 B (m) 0.45 5-10 10 H (m) 0.15 10-15 17 R (m) 0.8 15-25 25 A (m) 1.35 25-30 18 Q(m^3/s) 0.25 30-35 12 >35 7.5 9*B^2*H^2*visc 4.10E-07 PI*(roP-roG)*Q*A 2119.514754 Sez (m^2) 0.0675 Vconv (m/s) 3.703703704 D min (m) 1.39093E-05 D min (micron) 13.90934904 efficienza % numerica 62.5