EPS 2021 03

Full exam for Electric Power Systems in the Energy Engineering degree programme at Politecnico di Milano. The document covers: Electric Power Systems Exam #3: 09/09/2021 1Β° Part Exercise 1 In the figure bellow a three -phase demand (D) is supplied by a three -phase synchronous generator ( SG) through the electric line L. The demand absorbs 𝑃𝐷 =400+20βˆ™π‘΅ [MW] with a lagging power factor cosπœ‘π· =0.95.

Electric Power SystemsFull exam

Document information

What's included in this study material

Full exam for Electric Power Systems in the Energy Engineering degree programme at Politecnico di Milano. The document covers: Electric Power Systems Exam #3: 09/09/2021 1Β° Part Exercise 1 In the figure bellow a three -phase demand (D) is supplied by a three -phase synchronous generator ( SG) through the electric line L. The demand absorbs 𝑃𝐷 =400+20βˆ™π‘΅ [MW] with a lagging power factor cosπœ‘π· =0.95.

Import quality: text was extracted directly from the original document.

Extracted content from the document

Representative passages recognised in different parts of the material. The full extracted text remains available to search, while this compact preview makes the page easier to read.

Page 1

Electric Power Systems Exam #3: 09/09/2021 1Β° Part Exercise 1 In the figure bellow a three -phase demand (D) is supplied by a three -phase synchronous generator ( SG) through the electric line L. The demand absorbs 𝑃𝐷 =400+20βˆ™π‘΅ [MW] with a lagging power factor cosπœ‘π· =0.95. The electric transformer T nameplate specifies the following data: Nominal electrical power 600 MVA Nominal ideal transformer ratio 20/132 kV/kV Short-circuit voltage 10 % The synchronous generator SG nameplate specifies the following data: Nominal electrical power 700 MVA Nominal line-to-line voltage 20 kV Maximum phase-to-ground emf 24 kV Maximum turbine power 650 MW Stator winding resistance 0.2 Ξ© Synchronous reactance 0.03 Ξ© Stator phases connection D The demand is supplied at line-to-line voltage of 𝑉𝑠𝑒𝑝𝑝𝑙𝑦 =(95+𝑡) % of the nominal voltage at the secondary (high) voltage side of the transformer T. Determine: 1. the real and reactive power supplied by the synchronous generator to the grid (𝑃𝐺,𝑄𝐺) and the line-to-line voltage at the synchronous generator’s terminals (𝑉𝐺); 2. the emf 𝐸𝐸 and the load angle (𝛿) of the synchronous generator; 3. check the capability curve of the synchronous generator in the given operating conditions; NOTE: In the above data, N is the last number of the student’s Person Code/Codice Persona (e.g. if Person Code is 10381486 then N = 6); Please substitute accordingly. P su P Exercise 2 Consider the following electric network Line xl [p.u.] L1 0.1 L2 0.2 + 0.01βˆ™N L3 0.05 Generator Real power output: PG Voltage set- point: VG [p.u] [p.u] G 4.0 1.06 Demand Absorbed real power: PD Power factor [p.u] [-] D 5 + 0.2βˆ™N 0.93 – lagging Knowing that the inductive reactor I is characterized by a reactance 𝑋𝐼 = 2 p.u. and that the External Grid (Ext Grid) is modeled as an infinite…

Preview

First page of the document.

First page: EPS 2021 03