EPS 2021 04

Full exam for Electric Power Systems in the Energy Engineering degree programme at Politecnico di Milano. The document covers: Electric Power Systems Exam #4: 28/01/2022 1° Part Exercise 1 Consider a generation plant made of two identical synchronous machines connected in parallel to the plant terminals as shown in the figure bellow. Each synchronous machine is characterized by: Nominal apparent power

Electric Power SystemsFull exam

Document information

What's included in this study material

Full exam for Electric Power Systems in the Energy Engineering degree programme at Politecnico di Milano. The document covers: Electric Power Systems Exam #4: 28/01/2022 1° Part Exercise 1 Consider a generation plant made of two identical synchronous machines connected in parallel to the plant terminals as shown in the figure bellow. Each synchronous machine is characterized by: Nominal apparent power

Import quality: text was extracted directly from the original document.

Extracted content from the document

Representative passages recognised in different parts of the material. The full extracted text remains available to search, while this compact preview makes the page easier to read.

Page 1

Electric Power Systems Exam #4: 28/01/2022 1° Part Exercise 1 Consider a generation plant made of two identical synchronous machines connected in parallel to the plant terminals as shown in the figure bellow. Each synchronous machine is characterized by: Nominal apparent power 16 MVA Nominal operating voltage (line-to-line) 3 kV Phase synchronous reactance 1.3 Ω Phase resistance 0.2 Ω Maximum turbine mechanical power 15 MW emf 𝐸0 (phase-to-ground) at maximum excitation current 3.9 kV Stator windings connection Y In normal operating conditions the voltage at the plant terminals is equal to the nominal voltage of the synchronous machines, the two synchronous generators are equ ally loaded, the emf of both generators is 𝐸0 = 3.1 𝑘𝑉 while the load angle is 𝛿 = 25°. 1. compute the current phasor supplied by the generators to the plant’s load and the corresponding power factor; 2. compute the real and reactive powers supplied by the generators to the plant’s load; 3. considering that SG1 is producing the entire real power required by the plant’s load while SG2 the entire reactive power required by the plant’s load, compute the emf phasor 𝐸0̅̅̅ for each of the two synchronous generators of the plant; 4. for the operating conditions identified at point 3 check the capability limits for both synchronous generators of the plant. 5. considering the operating conditions identified at point 3 and assuming the plant’s load is constant, by how much must SG2 change its reactive power production such that SG1 operates at power factor 𝐜𝐨𝐬 𝝋𝟏 = 𝟎. 𝟗 – lagging maintaining constant its real power output. Exercise 2 Consider the following electric network Line xl [pu] L1 0.4 L2.1 0.3 L2.2 0.35 Generator Real power output: PG Operating voltage: VG [pu] [pu] G 1 1.02 Demand Absorbed apparent…

Preview

First page of the document.

First page: EPS 2021 04