Topic-based study materials for Advanced Building Physics in the Construction Engineering degree programme at Politecnico di Milano. The document covers: 1 Heat pump with various configurations of sources and sinks A heat pump is used in winter to maintain an indoor space at a given set-point temperature. The heat pump can be coupled to various external/internal heat sources/sinks: - Internal sink: radiators (at 80°C) or radiant
Topic-based study materials for Advanced Building Physics in the Construction Engineering degree programme at Politecnico di Milano. The document covers: 1 Heat pump with various configurations of sources and sinks A heat pump is used in winter to maintain an indoor space at a given set-point temperature. The heat pump can be coupled to various external/internal heat sources/sinks: - Internal sink: radiators (at 80°C) or radiant
Import quality: text was extracted directly from the original document.
Representative passages recognised in different parts of the material. The full extracted text remains available to search, while this compact preview makes the page easier to read.
1 Heat pump with various configurations of sources and sinks A heat pump is used in winter to maintain an indoor space at a given set-point temperature. The heat pump can be coupled to various external/internal heat sources/sinks: - Internal sink: radiators (at 80°C) or radiant floors (25°C) - External sources: external air (-10°C) or lake (15°C). a) Assuming that (i) the heat pump has an efficiency equal to 65% of that of a reversible heat pump operating at the same temperature levels, and (ii) the temperature in the evaporator is 5°C lower than the source, while the temperature in the condenser is 5°C higher than the sink, determine the COP in all 4 configurations. b) If the building has a floor area of 90m2, internal gains equal to 4 W/m2 and heat losses Qwalls = 2430 W, determine QH and the mechanical power required to the heat pump in all four cases. c) Determine the mechanical power of the reversible heat pump. Solution: a) COP (adim.) in all four configurations: external air lake radiators 2.33 3.10 radiant floor 4.38 9.85 b) Work (in W) required in all four configurations: external air lake radiators 889 667 radiant floor 473 210 a) Work (in W) required in all four configurations, reversible case: external air lake radiators 578 433 radiant floor 307 137 2 Winter air conditioning A room of a cinema must be maintained at internal conditions Ta=20°C and ϕa=50%, while external conditions are Te = 1°C and ϕe=80%. The overall heat losses to the outside are Qtot = -20000 kcal/h, and it is necessary to extract a mass-flow rate of water vapour 𝑚̇ 𝑣 = 20 𝑘𝑔𝑣/ℎ. The fresh air that must be introduced is 𝑚̇ 𝑑.𝑎.,𝑒𝑥𝑡 = 7000 𝑘𝑔𝑑.𝑎./ℎ. At Ti=35°C. Determine: - The heating power at the pre-heating and post-heating coils (Qpre-heating and Qpost-heating) - The mass flow rate of…