DIPARTIMENTO DI SCIENZE E TECNOLOGIE AEROSPAZIALI IMPIANTI E SISTEMI AEROSPAZIALI Laboratorio n.10 – A.A. 2016/2017 IMPIANTO DI CONDIZIONAMENTO Dati : 2m = 300 kg/h p1 = 101325 Pa p2/p1 = 3.2 p3 = .95 p2 p4 = p5 = p6 = p1 p7 =.95 p1 T4 = 4 °C calcolare per i due casi di temperatura al punto 1 di 10°C e di 30°C: x la ripartizione di portata richiesta fra il ramo “caldo” ( 5m) ed il ramo “freddo” (4m) per avere nel punto 6 la temperatura di 20 °C quando quella esterna è di 30°C e di 25°C quando quella esterna è di 10°C. x la portata d’aria (7m) necessaria nello scambiatore di calore per ottenere le temperature indicate e la temperatura T8. Coefficiente politropica valvola A: 05.1 J Coefficiente politropica valvola B: 37.1 J Efficacia dello scambiatore: 8.)( )( 727 323   TTm TTm  H Rendimento del compressore: 9. cK Rendimento della turbina: 9. tK B A 1 2 3 4 5 6 7 8