POLITECNICO DI MILANO - DIPARTIMENTO DI INGEGNERIA AEROSPAZIALE IMPIANTI E SISTEMI AEROSPAZIALI – LABORATORI, VERS IONE 2012 Laboratorio n. 9 Si prenda in considerazione il solito MD-11, con le seguenti caratteristiche di rilievo per l’impianto di pressurizzazione: Quota di tangenza: 43000 ft Lunghezza cabina: 46.5 m Diametro cabina: 5.7 m Durante una missione alla quota di crociera di 39000 ft, utilizza l’ECS con una portata d’aria esterna di 1.9 kg/s. Si richiede di: • calcolare la pressione differenziale di attivazion e valvole antiesplosione; • stabilire un andamento temporale della quota cabin a adeguato al soddisfacimento delle condizioni di progetto della fusoliera e del comfort dei passeggeri (tracciare un diagramma indicando i punti significativi); • tracciare l’andamento della portata uscente e del coefficiente di perdita della valvola di efflusso.