Back
NotesBy topic

Notes of Biomedical signal processing

Topic-based study materials for Biomedical Signal Processing and Medical Images in the Biomedical Engineering degree programme at Politecnico di Milano. The document covers: INTRODUCTION Biological systems: complex because of interactions among them, dynamical behavior (adaptive to external and internal changes), high inter- and intra-individual variability (the latter causes the non- stationarity of biological processes), predictable in relative

Biomedical Signal Processing and Medical ImagesBy topic

Document information

What's included in this study material

Topic-based study materials for Biomedical Signal Processing and Medical Images in the Biomedical Engineering degree programme at Politecnico di Milano. The document covers: INTRODUCTION Biological systems: complex because of interactions among them, dynamical behavior (adaptive to external and internal changes), high inter- and intra-individual variability (the latter causes the non- stationarity of biological processes), predictable in relative

Import quality: text was extracted directly from the original document.

Extracted content from the document

Representative passages recognised in different parts of the material. The full extracted text remains available to search, while this compact preview makes the page easier to read.

Page 1

INTRODUCTION Biological systems: complex because of interactions among them, dynamical behavior (adaptive to external and internal changes), high inter- and intra-individual variability (the latter causes the non- stationarity of biological processes), predictable in relative terms, signals corrupted by endogenous or exogenous noise (we assume an addictive model); flow chart of the decision process: Type of signals: ECG: determinist quasi-periodic, Action potential: deterministic transient, EEG: stochastic stationary (in short windows), EMG: stochastic non-stationary (in short windows) Methodology approaches: deterministic, when the parameters of interest are a priori known, it is only necessary to measure them; stochastic, when the parameters are not a priori known, it is necessary to use statistical methods; biological systems are mainly deterministic or mainly stochastic Strictly stationary process: all statistical moments are constant on the whole temporal window; weakly stationary process: mean and ACF are constant on the whole temporal window Ergodic process: all the statistical properties can be estimated using a single realization For a discrete-time signal mean and autocorrelation function (i.e., the correlation between two instants of the process depending on the delay that divides them) are defined as: In practice, mean and autocorrelation function are estimated from a finite number of samples; the sample mean estimates the real mean with uncertainty σ/√N, where σ = r(0) is the variance: Frequency bands and ranges of signals: ECG (frequency range: 0.05-200 Hz) up to 5 mV for adults and to 10 μV for fetuses, EEG (0.5-70 Hz) up to 100 μV, EMG (10-200 Hz) up to 5 mV but it’s highly dependent on the electrode placement, ABP (DC-20 Hz for indirect measures,…

Preview

First page of the document.

First page: Notes of Biomedical signal processing