The synchronous machine

Topic-based study materials for Electric Power Systems in the Energy Engineering degree programme at Politecnico di Milano. The document covers: EXERCISES FOR ELECTRIC POWER SYSTEMS COURSE ENERGY DEPARTMENT, Electrical section Class 5 The Synchronous Machine Exercise 1 For a three-phase Y-connected, 1 MVA, 500 V, 50 Hz synchronous machine the open-circuit characteristic /g1831 /g2868/g3404

Electric Power SystemsBy topic

Document information

What's included in this study material

Topic-based study materials for Electric Power Systems in the Energy Engineering degree programme at Politecnico di Milano. The document covers: EXERCISES FOR ELECTRIC POWER SYSTEMS COURSE ENERGY DEPARTMENT, Electrical section Class 5 The Synchronous Machine Exercise 1 For a three-phase Y-connected, 1 MVA, 500 V, 50 Hz synchronous machine the open-circuit characteristic /g1831 /g2868/g3404

Import quality: text was extracted directly from the original document.

Extracted content from the document

Representative passages recognised in different parts of the material. The full extracted text remains available to search, while this compact preview makes the page easier to read.

Page 1

EXERCISES FOR ELECTRIC POWER SYSTEMS COURSE ENERGY DEPARTMENT, Electrical section Class 5 The Synchronous Machine Exercise 1 For a three-phase Y-connected, 1 MVA, 500 V, 50 Hz synchronous machine the open-circuit characteristic /g1831 /g2868/g3404 /g1858/g4666/g1835/g3032/g3051/g3030 /g4667, and the short- circuit characteristic, /g1835/g3046/g3030 /g3404 /g1858/g4666/g1835/g3032/g3051/g3030 /g4667, are given in the figure. The characteristics are referred to the line-to-ground voltage of the stator windings. The phase resistance of the synchronous machine is 0.01 Ω. Answer the following questions: 1. determine the phase synchronous impedance characteristic of the machine, /g1852 /g3046/g3404 /g1858/g4666/g1835/g3032/g3051/g3030 /g4667; 2. assuming the synchronous impedance constant and equal to the nominal value, determine the induced emf phasor ( /g1831 /g2868/g3364/g3364/g3364) for each of the below described load conditions, such that the voltage at the machine terminals is constant and equal to the nominal voltage of the machine: 2.1. the real power demand of the load is /g1842/g3005/g34040.6 MW and the power factor is: cos /g2030/g3005/g34040.9 – lagging ( RL load); cos /g2030/g3005/g34041 (R load) and cos /g2030/g3005/g34040.9 – leading ( RC load). 2.2. the load absorbs a reactive power of /g1843/g3005/g3404 0.2 Mvar with a power factor of cos /g2030/g3005/g3404 0 (L load); 2.3. the load injects a reactive power of /g1843/g3005/g3404 0.2 Mvar with a power factor of cos /g2030/g3005/g3404 0 (C load); 3. the external characteristics of the machine, /g1848/g3364/g3404 /g1858/g4666/g1835̅/g4667, considering the open-circuit voltage at the machine terminals equal to 500 V and the machine operating with constant excitation current and constant power factor of cos…

Preview

First page of the document.

First page: The synchronous machine