Back
ExamFull examExam paper only

03 07 15 2

Full exam for Technologies for Sensors and Clinical Instrumentation in the Biomedical Engineering degree programme at Politecnico di Milano. The document covers: Grade of written test: Final grade: Grade of project: Signature: Technologies for Sensors and Clinical Instrumentation 3 July 2015 FAMILY NAME ……………………….… NAME ….…………………. MATR ………… PREFERENCE for ORAL: † 9 July (morning) † 9 July (afternoon) † 10 July (morning) † 10 July

Technologies for Sensors and Clinical InstrumentationFull exam

Document information

What's included in this study material

Full exam for Technologies for Sensors and Clinical Instrumentation in the Biomedical Engineering degree programme at Politecnico di Milano. The document covers: Grade of written test: Final grade: Grade of project: Signature: Technologies for Sensors and Clinical Instrumentation 3 July 2015 FAMILY NAME ……………………….… NAME ….…………………. MATR ………… PREFERENCE for ORAL: † 9 July (morning) † 9 July (afternoon) † 10 July (morning) † 10 July

Import quality: text was extracted directly from the original document.

Extracted content from the document

Representative passages recognised in different parts of the material. The full extracted text remains available to search, while this compact preview makes the page easier to read.

Page 1

Grade of written test: Final grade: Grade of project: Signature: Technologies for Sensors and Clinical Instrumentation 3 July 2015 FAMILY NAME ……………………….… NAME ….…………………. MATR ………… PREFERENCE for ORAL: † 9 July (morning) † 9 July (afternoon) † 10 July (morning) † 10 July (morning) † next calls Notes: - Answers are considered complete only if units of measurement are indicated. - Only answers on this sheets are considered for evaluation. - Questions are independent from each other. Q.1) (8 points) A temperature sensor catheter is designed for thermo-dilution measurements. The adopted sensor is a thermistor, which characteristic ሻ is represented by the following expression: ܴ଴݁ ఉሺଵ ்ିଵ ்బ ሻ ܴ଴ (equal to Ω݇is the thermistor resistance at ambient temperature ܶ଴ܭand ߚis the material constant of the thermistor (equal to 4000 K). The thermistor has a dissipation coefficient ߜ in blood equal to ܭ/ܹ݉ . The conditioning circuit consists of a Wheatstone bridge (1/4 bridge). The circuit is modified by shunting the sensor ݐܴwith a resistor ݌ܴin order to linearize the measurements around the body temperature ܶ௕ܭ . 1 - 1.a) The parallel resistor value is chosen according to the following formula: ்ܴሺܶ௕ሻ∙ ఉିଶ்್ ఉାଶ்್ . Explain how this formula can be obtained (computations are not required). Compute the value of ݌ܴ . …………………………………………………………… ..……………………………………………………………………………………………………… ..……………………………………………………………………………………………………… ..……………………………………………………………………………………………………… ..……………………………………………………………………………………………………… 2 - 1.b) The “shunted” sensor ܴ// ൌ ோ௣ோ௧ ோ௣ାோ௧ can be assumed to have a linear response to ሺܾܶሻ: ܴ// ܴ// ்್ ∙ሺ 1൅ ௗோ// ௗ்|்ୀ்್ ∙ ଵ ோ//೅್ ܶ௕ܴ// ்್ ܶ௕ሻሻ. Show that ൌെ 0 . 0 1 8 Ω Ω ܭିଵ. ……………………………………………………………………………………………………….. ………………………………………………………………………………………………………..…

Preview

First page of the document.

First page: 03 07 15 2