Document information
- University
- Politecnico di Milano
- Degree programme
- Energy Engineering
- Subject
- Energy Conversion A
- Classification
- Other study material
- Original format
- Text
- Searchable text
University study material for Energy Conversion A in the Energy Engineering degree programme at Politecnico di Milano. The document covers: Fifth project: comparison of advanced steam cycle architectures Simone Fedeli 892133 Luca Grippo 829683 Filippo Mecarelli 892120 Francesco Persico 893256 November 2017 1 The purpose of this analysis is to compare the performance of six dierent con gurations of a USC steam
University study material for Energy Conversion A in the Energy Engineering degree programme at Politecnico di Milano. The document covers: Fifth project: comparison of advanced steam cycle architectures Simone Fedeli 892133 Luca Grippo 829683 Filippo Mecarelli 892120 Francesco Persico 893256 November 2017 1 The purpose of this analysis is to compare the performance of six dierent con gurations of a USC steam
Import quality: text was extracted directly from the original document.
Representative passages recognised in different parts of the material. The full extracted text remains available to search, while this compact preview makes the page easier to read.
Fifth project: comparison of advanced steam cycle architectures Simone Fedeli 892133 Luca Grippo 829683 Filippo Mecarelli 892120 Francesco Persico 893256 November 2017 1 The purpose of this analysis is to compare the performance of six dierent con gurations of a USC steam plant. We consider the rst con guration as the reference one, while in the others we have some key changes, as follows: Con guration A • superheater outlet mass ow rate: 1850000 kg/h; • superheater outlet steam pressure: 270 bar; • number of reheats: 1; • number of preheaters (deaerator included): 8, of which 4 for LP and 4 for HP; • number of mid-pressure two- ow rotors: 1; • number of low-pressure two- ow rotors: 2; • last stage blading: 33.5 inches - mean diameter 99.5 inches; • steam temperatures: 580 /580 ; • condensing pressure: 0.05 bar; • fuel: coal; • exhaust gases stack temperature: 150 ; • O2 concentration in exhaust gases at the stack: 5%; • economizer water inlet temperature: 315 . Con guration B • fuel: natural gas; • exhaust gases stack temperature: 120 ; • stack O2 concentration in exhausts: 2.5%. Con guration C • condensing pressure: 0.1 bar. Con guration D • steam temperatures: 640 /640 . Con guration E • number of preheaters: 4, of which 2 for LP (including deaerator) and 2 for HP; • economizer water inlet temperature: 280 . Con guration F • number of reheats: 2; • steam temperatures: 580 /580 /580 . 2 1 Second-law analysis of all con gurations First of all we analyze all con gurations with a second-law perspective in order to better understand the liabilities of each con guration. Using the software CicVap we have come to the following plot: As we can see, all con gurations have roughly the same second-law e ciency which stands between 40.5 and 43.4%. Being…
First page of the document.